Current Transducer HAW 03 .. 20-P
IPN =
3 .. 20 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Preliminary
Electrical data
Primary nominal
r.m.s. current
IPN (A)
Primary current
measuring range
IP (A)
3
5
10
15
20
VC
IC
Vd
R IS
VOUT
ROUT
RL
Primary Conductor
Diameter
(mm)
± 7.5
± 13
± 25
± 38
± 50
0.8
0.9
1.1
1.4
1.6
Type
HAW 03-P
HAW 05-P
HAW 10-P
HAW 15-P
HAW 20-P
Supply voltage (± 5 %)
± 15
Current consumption
500
Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C
±4
Output internal resistance
100
Load resistance
>10
Features
V
mA
kV
MΩ
V
Ω
kΩ
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2000 V
• Low power consumption
• Extended measuring range(2.5x IPN)
Advantages
• Easy mounting
• Small size and space saving
• Only one design for wide current
Accuracy-Dynamic performance data
X
ε
L
VOE
VOH
VOT
TCε G
tr
f
Accuracy @ IPN, TA = 25°C (without offset)
Linearity (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN
Thermal drift of VOE
max.
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Frequency bandwidth (- 3 dB)1)